AM-DEF-7000 Defibrillator Monitor (AED and Manual)

Defibrillator

  • Waveform: Biphasic
  • Energy Display: Monitor display indicates both selected and delivered energy
  • Charge Prompt Type: Voice and visual prompts
  • Electrode Impedance Measurement Range: 0-250 0hms
Category:

Technical specifications

Display

  • Screen Type: High-resolution display
  • Screen Size: 7 inches (1 7.7 cm) diagonally
  • Sweep Speed: 25mm/sec
  • Information: Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits Delivered Energy

Defibrillator

  • Waveform: Biphasic
  • Energy Display: Monitor display indicates both selected and delivered energy
  • Charge Prompt Type: Voice and visual prompts
  • Electrode Impedance Measurement Range: 0-250 0hms

AED Mode

  • AED Function: Auto analyzes and charges x3 with programmable auto energy level selection, screen prompts, and voice prompts
  • Shockable Rhythms: Ventricular fibrillation, Ventricular tachycardia, QRS complex wave duration
  • Charge Control:  Control on device front panel, press key on paddle

Manual Mode

  • Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 Joule
  • Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor

ECG Monitoring

  • Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles
  • Lead Selection: Displayed on monitor, paddles, l, II, III, AVR, AVL, AVF, V
  • ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor
  • Heart Rate: 20-300BPM
  • Heart Rate Alarm: On/Off displayed on monitor, user-selectable
  • Smart Alarms: Beeper/Voice prompts indicate shockable rhythm

SpO2 Module

  • Measurement Range: 30-100%, +2% between 80%-90%, others + 5%
  • Alarm Range: User set high limit and low limit
  • Alarm Accuracy: +10% within setting values
  • Alarm Time Accuracy: Less than 12 sec

Recorder

  • Paper: 50mm thermal
  • Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay
  • Printing Method: High-resolution, thermal array print head
  • Print-out Modes: Manual or automatic, user-configurable
  • On/Off Control: Front panel and paddle
  • Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge

Battery

  • Type: Rechargeable, Ni-MH battery, 12V
  • Operating Time: For a new, fully charged battery 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions

Pacer

  • Pacer function is optional