High Frequency Mobile Surgical X-ray System AM-AR-M20E

Usage

Orthopedics: osteopathy, displaces, nailing.

Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.

Category:

Features

  1. New integrated design, compact appearance, convenient operation.
  2. Unique hand-held remote controller, more convenient operation
  3. Graphical colorfully LCD touch screen console interface, convenient operation, fashionable design.
  4. High-quality combined HF-HV X-ray generator, greatly reducing the X-ray irradiation.
  5. Toshiba image intensifier is employed, stable and reliable in quality, high-definition image and display system.
  6. With the perspective KV, MA auto8matic tracking feature, the image brightness and definition are automatically set at optimal function.
  7. Integrated digital acquisition and processing system make the operation more convenient.

III. Configuration

1, New (with electric auxiliary support arm) C-arm main rack    1 set

2, High-frequency high-voltage X-ray generator and high-frequency inverter power supply

(5KW,40KHZ,120KV)                                     1 set

3, Toshiba 9-inch image intensifier                           1 set

4, Megapixel ultra-low-light digital cameras                   1 set

5, Integrated digital acquisition and processing system         1 set

6, High-thickness grids                                      1 set

7, Electric adjustable collimator                              1 set

8, 24-inch LCD monitor, resolution:1920*1080                 1 set

9, Unique hand-held remote controller                        1 set

  1. Technical Specifications
PARAMETER SPECIFICATION
Fluoroscopic

Capacity

Max rated capacity Tube Current 4mA,
Tube Voltage 120kV
Automatic Fluoroscopy Tube Voltage:40kV~120kV Adjust Automatically
Tube Current 0.3mA~4mA set manually
Manual Fluoroscopy Continuous Tube Voltage:40kV~120kV
Continuous Tube Current  0.3mA~4mA
Pulse Fluoroscopy Continuous Tube Voltage 40kV~120kV
Continuous Tube Current 0.3mA~30mA
Photography Capacity Max rated capacity 5 KW
 

Tube Voltage and Current Combination

 

40kV~49kV 1 ~180 mAs
50kV~59kV 1 ~140 mAs
60kV~69kV 1 ~125 mAs
70kV~79kV 1 ~110 mAs
80kV~89kV 1 ~100 mAs
90kV~99kV 1 ~80 mAs
100kV~109kV 1 ~63 mAs
110kV~120kV 1 ~50 mAs
Plateholder Size 200mm×250mm(8″×10″) or

250mm×300m(10″×12″)

X-ray Tube X-ray Tube Special for High Frequency
Fixed anode Dual focus large focus: 1.5, small focus: 0.3 (Advantage)
Inverter Frequency: 40KHz
Thermal capacity: 35KJ (47KHU)
Video System Image Intensifier Image Intensifier made by TOSHIBA (9″,6″,4.5″)
CCD Vidicon Ultralow light megapixel CCD camera imported from Japan
Monitor 23inch Horizontal 1280 lines and vertical 1024 lines,
Bandwidth : 48MHz, Image/sec : 75

grayscale: ≥ 11

Line pairs resolution: ≥ 1.2 LP / mm

Integrated digital acquisition and processing system Registration: registration, medical records, Worklist

Collection: Start collection; prepare video, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass, negative image

Open silhouette, edge enhancement, recursive noise reduction

Processing; four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement report: save, preview, expert template

Dicom features: Dicom browsing, web service

Structure Directive wheel ±90°revolution can freely change the moving  direction of the unit
Ascending & Descending Range of Pillar ≥400mm
C-arm Forward and Backward Movement: 200mm
Revolution around Horizontal Axis ±180°
Revolution around Vertical Axis ±15°( Advantage), better than others’  ±12.5°, easier to take special positions radiography)
Slip on orbit 120°(+90°~ 30°)
Frame monitor rotation ≥ 300 °