Features
1.15” TFT LCD screen displays the Ventilation parameters, Alarming information and oscillograms, make every operation more easily.
Multiple ventilation modes, suitable for ICU, emergency department and operation room etc:(PRVC,APRV,DUOLEVEL,V-SIMV,P-SIMV,IPPV,A/C,PCV,PSV,SPONT/CPAP, SIGH, MANUAL)
2.5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
3.Humidifier can heat and wet breathing gas,makes it comfortable for patient to breathe
4.Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes.
5.Nebulization make medicine into small liquid and particle, easier and quicker for patient to breathe in.
6.High temperature resistance breathing circuit is reusable and anti-pollution.
Safety
1.14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
2.Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration
3.Easy to move with four casters, easy to stop with two brakes
4.Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
5.Compact long life internal battery can provide emergency power, avoid risk of patient
6.Self-check before operation, eliminate system mistake
Technical Specifications
NAME | PARAMETER |
Ventilation modes | PRVC,APRV,DUOLEVEL,V-SIMV,P-SIMV,IPPV,A/C,PCV,PSV,SPONT/CPAP, SIGH, MANUAL |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0~2000mL |
Frequency (Freq) | 1min~100min |
Oxygen concentration | 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O~ 40 cmH2O |
Pressure Triggering Sensitivity (Ptr) | -20cmH2O~20cmH2O (Based on PEEP) |
Flow Triggering Sensitivity (Ftr) | 0.5L/min~30L/min |
Pressure Control | 5cmH2O~80cmH2O |
Pressure Support | 0cmH2O~80cmH2O |
SIGH | 0(off) 1/100~5/100 |
Apnea Ventilation | OFF, 5s~60s |
Pressure Limit | 20cmH2O~100cmH2O |
Monitored Parameters | |
Frequency (Freq) | 0 /min~ 100 /min |
Tidal volume(Vt) | 0 mL~ 2500 mL |
MV | 0L/min~99L/min |
Airway pressure | 0cmH2O~100cmH2O |
Dynamic Lung Compliance Testing | 1mL/cmH2O~1000mL/cmH2O |
Oxygen Concentration | 15%-100% |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm
Low Minute Volume alarm |
5L/min-99L/min
1L/min-30L/min |
High Airway pressure alarm
Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm |
20cmH2O-100cmH2O
0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning
Fan error Oxygen deficit |
5-60s
Show on screen Show on screen |
The maximum limited pressure | <12.5 kPa |
Working conditions | |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | 220V±22V |
Power frequency | 50Hz±1Hz |
Input power | 900VA(with air compressor)
250VA(without air compressor) |
Oscillogram | |
P-T | Pressure Time |
F-T | Flow-Time |
V-T | Volume Time |
P-V Loop | Pressure-Volume Loop |
F-V Loop | Flow Volume Loop |
P-F Loop | Pressure-Flow Loop |