Features
- Integrated Plug in Modular, 12.1” colorful and clear TFT display
- Standard 6 parameters and optional single plug-in parameter box
- Touch screen available; able to be operated by keyboard or optional mouse
- With durable trim knob and backlight silicone buttons
- Simultaneously display at least 10 parameters, 13 kinds of arrhythmia analysis
- ECG Waveforms of 7-lead displayed simultaneously.
- Assist to judge the heart activity directly
- 15 kinds of drug dose calculations
- Anti-electrosurgical, anti-defibrillation, suitable for monitoring critical care
- Trend interface, OxyCRG interface, BigFont interface
- Built-in detachable rechargeable lithium battery, battery life 4.5 hours
- 1000 hours trend data and trend graphs, 48 hours full waveform reviewing
- Power failure data store
- High capacity of information storage
- NIBP dual overpressure protection
- Wired/wireless connection, with system supporting 3 display screens
- Supporting SD card, 4 USB interfaces
- Omni-directional visible design; 3 levels of audible, visual and audio alarm; dual alarm lights for physiological and technical alarm
Technical specification
ECG
- Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
- Lead selection: I, II, III, avR, avL, avF, V,
- Waveform: 2 ch
- Lead mode: 3 Leads (R, L, F or RA, LA, LL)
- Lead selection: I, II, III,
- Waveform: 1 ch
- Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
Heart Rate
- Range
- Adult: 15 ~ 300 bpm
- Neo/Ped: 15 ~ 350 bpm
- Accuracy: ± 1% or ± 1bpm, which great
- Resolution: 1 bpm
- Sensitivity: > 200 (uV P-P)
- Differential Input Impedance: > 5 MΩ
- CMRR
- Monitor: > 105 dB
- Operation: > 105 dB
- Diagnosis: > 85 dB
- Electrode offset potential: ±300mV
- Leakage Current: < 10 uA
- Baseline Recovery: < 3 S after Defi.
- ECG Signal Range: ±8 m V (Vp-p)
- Bandwidth
- Surgery: 1 ~ 15 Hz
- Monitor: 0.5 ~ 35 Hz
- Diagnostic: 0.05 ~ 100 Hz
- Calibration Signal: 1 (mV p-p), Accuracy: ±5%
- ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
- ARR Detecting
- Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
- Alarm: Available
- Review: Available
Respiration
- Method: Impedance between R-F (RA-LL)
- Differential Input Impedance: >2.5 MΩ
- Measuring Impedance Range: 0.3~5.0Ω
- Base line Impedance Range: 0 – 2.5 KΩ
- Bandwidth: 0.3 ~ 2.5 Hz
- Resp. Rate
- Measuring and Alarm Range
- Adult: 0 ~ 120 rpm
- Neo/Ped: 0 ~ 150 rpm
- Resolution: 1 rpm
- Accuracy: ±2 rpm
- Apnea Alarm: 10 ~ 40 S
NIBP
- Method: Oscillometric
- Mode: Manual, Auto, STAT
- Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
- 120, 180, 240,480 (Min)
- Measuring Period in STAT Mode: 5 Min
- Pulse Rate Range: 40 ~ 240 bpm
- Alarm Type: SYS, DIA, MEAN
- Measuring and alarm range
- Adult Mode
- SYS: 40 ~ 270 mmHg
- DIA: 10 ~ 215 mmHg
- MEAN: 20 ~ 235 mmHg
- Pediatric Mode
- SYS: 40 ~ 200 mmHg
- DIA: 10 ~ 150 mmHg
- MEAN: 20 ~ 165 mmHg
- Neonatal Mode
- SYS: 40 ~ 135 mmHg
- DIA: 10 ~ 100 mmHg
- MEAN: 20 ~ 110 mmHg
- Resolution Pressure: 1mmHg
- Accuracy Pressure Maximum Mean error: ±5mmHg
- Maximum Standard deviation: ±8mmHg
- Overpressure Protection
- Adult Mode: 297±3 mmHg
- Pediatric Mode: 240±3 mmHg
- Neonatal Mode: 147±3 mmHg
SpO2
- Measuring Range: 0 ~ 100 %
- Alarm Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified
- Actualization interval: about 1 Sec.
- Alarm Delay: 10 Sec.
Pulse Rate
- Measuring and Alarm Range: 20~300bpm
- Resolution: 1bpm
- Accuracy: ±2bpm
Temperature
- Channel: 2
- Measuring and Alarm Range: 0 ~ 50 °C
- Resolution: 0.1°C
- Accuracy: ±0.1°C
- Actualization interval: about 1 Sec.
- Average Time Constant:<10 Sec.
Configuration
- Standard: ECG, RESP, NIBP, SPO2, PR, TEMP
- Optional Function: Recorder, 2-IBP, VGA, ETCO2, AG (Anesthesia Gas), CO (Cardiac Output), Touch Screen, WIFI, Central Monitoring System.
Reviews
There are no reviews yet.