AM-800D Modular Patient Monitor

Our modular patient monitor can achieve modularization for function expansion with the help of integration plug-in technology, which can meet the requirement of updating the monitors in all departments in the hospital. With various functions, this machine can satisfy the convenient operation and the selection of all data of monitor in all departments in the hospitals.

Category:

Features

  • Integrated Plug in Modular, 12.1” colorful and clear TFT display
  • Standard 6 parameters and optional single plug-in parameter box
  • Touch screen available; able to be operated by keyboard or optional mouse
  • With durable trim knob and backlight silicone buttons
  • Simultaneously display at least 10 parameters, 13 kinds of arrhythmia analysis
  • ECG Waveforms of 7-lead displayed simultaneously.
  • Assist to judge the heart activity directly
  • 15 kinds of drug dose calculations
  • Anti-electrosurgical, anti-defibrillation, suitable for monitoring critical care
  • Trend interface, OxyCRG interface, BigFont interface
  • Built-in detachable rechargeable lithium battery, battery life 4.5 hours
  • 1000 hours trend data and trend graphs, 48 hours full waveform reviewing
  • Power failure data store
  • High capacity of information storage
  • NIBP dual overpressure protection
  • Wired/wireless connection, with system supporting 3 display screens
  • Supporting SD card, 4 USB interfaces
  • Omni-directional visible design; 3 levels of audible, visual and audio alarm; dual alarm lights for physiological and technical alarm

Technical specification

ECG

  • Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
  • Lead selection: I, II, III, avR, avL, avF, V,
  • Waveform: 2 ch
  • Lead mode: 3 Leads (R, L, F or RA, LA, LL)
  • Lead selection: I, II, III,
  • Waveform: 1 ch
  • Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto

Heart Rate

  • Range
    • Adult: 15 ~ 300 bpm
    • Neo/Ped: 15 ~ 350 bpm
  • Accuracy: ± 1% or ± 1bpm, which great
  • Resolution: 1 bpm
  • Sensitivity: > 200 (uV P-P)
  • Differential Input Impedance: > 5 MΩ
  • CMRR
    • Monitor: > 105 dB
    • Operation: > 105 dB
    • Diagnosis: > 85 dB
  • Electrode offset potential: ±300mV
  • Leakage Current: < 10 uA
  • Baseline Recovery: < 3 S after Defi.
  • ECG Signal Range: ±8 m V (Vp-p)
  • Bandwidth
    • Surgery: 1 ~ 15 Hz
    • Monitor: 0.5 ~ 35 Hz
    • Diagnostic: 0.05 ~ 100 Hz
  • Calibration Signal: 1 (mV p-p), Accuracy: ±5%
  • ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
  • ARR Detecting
  • Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
  • Alarm: Available
  • Review: Available

Respiration

  • Method: Impedance between R-F (RA-LL)
  • Differential Input Impedance: >2.5 MΩ
  • Measuring Impedance Range: 0.3~5.0Ω
  • Base line Impedance Range: 0 – 2.5 KΩ
  • Bandwidth: 0.3 ~ 2.5 Hz
  • Resp. Rate
  • Measuring and Alarm Range
    • Adult: 0 ~ 120 rpm
    • Neo/Ped: 0 ~ 150 rpm
  • Resolution: 1 rpm
  • Accuracy: ±2 rpm
  • Apnea Alarm: 10 ~ 40 S

NIBP

  • Method: Oscillometric
  • Mode: Manual, Auto, STAT
  • Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
  • 120, 180, 240,480 (Min)
  • Measuring Period in STAT Mode: 5 Min
  • Pulse Rate Range: 40 ~ 240 bpm
  • Alarm Type: SYS, DIA, MEAN
  • Measuring and alarm range
  •   Adult Mode
    • SYS: 40 ~ 270 mmHg
    • DIA: 10 ~ 215 mmHg
    • MEAN: 20 ~ 235 mmHg
  •   Pediatric Mode
    • SYS: 40 ~ 200 mmHg
    • DIA: 10 ~ 150 mmHg
    • MEAN: 20 ~ 165 mmHg
  • Neonatal Mode
    • SYS: 40 ~ 135 mmHg
    • DIA: 10 ~ 100 mmHg
    • MEAN: 20 ~ 110 mmHg
  • Resolution Pressure: 1mmHg
  • Accuracy Pressure Maximum Mean error: ±5mmHg
  • Maximum Standard deviation: ±8mmHg
  • Overpressure Protection
    • Adult Mode: 297±3 mmHg
    • Pediatric Mode: 240±3 mmHg
    • Neonatal Mode: 147±3 mmHg

SpO2

  • Measuring Range: 0 ~ 100 %
  • Alarm Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified
  • Actualization interval: about 1 Sec.
  • Alarm Delay: 10 Sec.

Pulse Rate

  • Measuring and Alarm Range: 20~300bpm
  • Resolution: 1bpm
  • Accuracy: ±2bpm

Temperature

  • Channel: 2
  • Measuring and Alarm Range: 0 ~ 50 °C
  • Resolution: 0.1°C
  • Accuracy: ±0.1°C
  • Actualization interval: about 1 Sec.
  • Average Time Constant:<10 Sec.

Configuration

  • Standard: ECG, RESP, NIBP, SPO2, PR, TEMP
  • Optional Function: Recorder, 2-IBP, VGA, ETCO2, AG (Anesthesia Gas), CO (Cardiac Output), Touch Screen, WIFI, Central Monitoring System.