Application
The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments.
Integrated AG module for choose.
Professional design for adult, child and infant inhalation anesthesia and respiratory management, with advanced ventilation modes.
Outstanding ergonomic design, it ranks high level in safty, stability and convenience as well as user experiences.
S6100 PLUS high-end model combine proven ventilation technology with the latest refinements in ergonomics and systems integration with an advanced, easy to use anesthesia table designed together with experienced experts to streamline your anesthesia workflow.
Trustpoint
- Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
- Safty design: Vaporizer with temperature, pressure, flow compensation and self-lock function.
- Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.
- Alarm: Three level alarm system, visual and sound alarm information.
- Power: Built-in battery ensure 2-3 hours using when power failure.
- Separate design of electric circuit and gas circuit ensure long using life.
- Flexible configurations able to customize your requirements.
- Designed and manufactured by Superstar Medical with over 25 years experience in this area.
- Altitude compensation:Suitable for high/low altitude areas
VENTILATION MODE | ALARM AND PROTECTION | ||
---|---|---|---|
IPPV, A/C, PCV,PSV, SIMV, SIGH, MANUAL | The AC power failure alarm | Power failure or no connection | |
Internal battery backup low voltage alarm | < 11.3 ± 0.3 V | ||
Ventilator parameter range | No tidal volume | ≤ 5 mL within 6 s | |
Flowmeter | O2(0.1 ~ 10 L/min) | High oxygen concentration alarm | 19% ~ 100% |
N2O (0.1 ~ 10 L/min) | Low oxygen concentration alarm | 18% ~ 99% | |
AIR (0.1 ~ 10 L/min) | High airway pressure alarm | 20cmH2O ~ 100cmH2O | |
Rapid oxygen supply | 25 L/min ~ 75 L/min | Low airway pressure alarm | 0cmH2O ~ 20cmH2O |
Tidal volume(Vt) | 0, 20 mL ~ 1500 mL | High minute volume alarm | Adult (5 L/min ~ 20 L/min) |
Frequence(Freq) | 1 /min ~ 100 /min | Low minute volume alarm | Paed (1 L/min ~ 15 L/min, 0 ~ 10 L/min) |
I:E | 4:1 ~ 1:8 | Continuous pressure alarm | (PEEP+1.5kPa) over 16s |
PEEP | 0 cmH2O ~ 30 cmH2O | Suffocation warning | 5s-60s no spontaneous ventilation |
Pressure triggering sensitivity(PTr) | -20 cmH2O ~ 0 cmH2O(Based on PEEP) | The maximum limited pressure | <12.5 kPa |
Flow trigger sensitivity(FTr) | 0.5 L/min ~ 30 L/min | Fan error | Show on screen |
Pressure control (PC) | 5 cmH2O ~ 60 cmH2O | Oxygen deficit | Show on screen |
SIGH | 0 (off) 1/100 ~ 5/100 | ||
Apnea ventilation | OFF, 5 s ~ 60 s | Working condition | |
Pressure limit | 20 cmH2O ~ 100 cmH2O | Gas source | O2, N2O, AIR |
Pressure | 280 kPa ~ 600 kPa | ||
Monitoring parameter | Voltage | 100 ~ 240 V | |
Frequence(Freq) | 0 /min ~ 100 /min | Power frequency | 50/60 Hz |
Tidal volume (Vt) | 0 mL ~ 2000 mL | ||
MV | 0 L/min ~ 100 L/min | ||
Oxygen concentration | 15 % ~ 100 % | Packing size | |
Wooden case packing size | L 870 * W 890 * H 1510 mm | ||
Oscillogram | G.W. | 195 KG | |
P-T (pressure – time) | CBM | 1.17 m3 | |
F-T (flow – time) | Anesthesia machine size | L 930 * W 750 * H 1405 mm | |
V-T (volume – time ) | N.W. | 124 KG | |
ETCO2-T (ETCO2– time) | |||
P-V loop (pressure – volume loop) |