Heat disinfection system
– Adopt the heat disinfection system to disinfect RO membrane, RO water supplying tube, tube for connecting with hd machine and port.
- No chemical leftover
- Environmental protection
- No endotoxin leftover
Frequency converter control system
- Apply the frequency converter and microelectronics technology to control the power control system of AC motor through changing the frequency of the motor.
- Strictly control the water temperature in the range between 85 and 95℃.
Online Monitoring
– Online chlorine and hardness monitoring
Bacteria Filter
– Remove the endotoxin in RO water by constant UF.
– Belowing items in the recycling RO water in tube can be removed.
- microorganism
- Suspicious particles
- biofilm fragment
- endotoxin
Water Treatment System
– Sediment filter (With automatic rinsing device): Removal of particulate and ferri ion from the water
– Carbon filter (With automatic rinsing device): Removal of chlorine and soluble organic matter.
– Softener filter (With automatic rinsing and regeneration device): Remove calcium and magnesium from the water so as to decrease the hardness of water.
– Guard filter: Designed to remove particles in the range 1 to 5 microns in diameter so as to protect the RO membrane.
– RO model: Removal of the ion, bacteria, pyrogen and so on.
– RO water supply: The design of constant pressure inside circulation tube can ensure the safety and stability of hd treatment.
– Controller: Automatic system
– Disinfection device: Automatic disinfection control system, safe and user friendly.
Parameter and Function
– Water quality: AAMI/ASAIO standard.
– High quality of RO membrane (DOW), booster pump and controller.
– These automatic functions including flushing after machine is on, interval rinsing and disinfection ensure convenience as it is no need for users to wait.
– The design of seamless membrane house and no dead angle in circulation tube avoid bacteria growth effectively.
– First and second grade can be used separately so as to ensure normal water production during maintenance.
– Constant pressure supply in soft water tank further ensures the stability of the device and safety of the water quality.
– These monitoring and alarming functions including on line water quality, no water, pressure and voltage enhance the safety of the device.
– Recycle the concentrated water so as to save water.
– Sanitary materials, compact design and touch screen interface.
– Remote online monitoring (Optional function).
Technical Specifications
Model | Water Rate(L/H)25℃ | Apply Data(bed) |
ROI-300/ROII-300 | ≥300 | 6 |
ROI-500/ROII-500 | ≥500 | 10 |
ROI-600/ROII-600 | ≥600 | 12 |
ROI-750/ROII-750 | ≥750 | 18 |
ROI-1000/ROII-1000 | ≥1000 | 24 |
ROI-1250/ROII-1250 | ≥1250 | 30 |
ROI-1500/ROII-1500 | ≥1500 | 35 |
ROI-2000/ROII-2000 | ≥2000 | 46 |
ROI-2500/ROII-2500 | ≥2500 | 58 |